Description
- RS provides outstanding performance in short-term centrifugation, effective with blood bags and large sample volumes. Maximum capacity of 6 x 2,000ml or 12 x 750ml blood bag system.
- High stability even at high centrifugation speeds makes the ROTO SILENTA 630RS a robust and highly efficient centrifuge. When in use, the large capacity refrigerated centrifuge is located on a high-quality shock absorber.
To ensure mobility, it is provided with a wheel system and the ROTO SILENTA 630RS can be raised and lowered as required. - Optimal running performance ensures the best results. Low noise level makes working conditions easy. Extensive centrifuge buckets and adapters for blood tubes, standard tubes, bottles and blood bag systems can be centrifuged in the same rotor – no need to replace the rotor.
- The Hettich HettInfo data reporting system as well as customized solutions enable the achievement of CMP standards, high standards of user safety and product quality in blood transfusion centers.
Efficiency
- High centrifugal force (RCF) up to 6,520 x g at 4,500 min-1.
- Maximum large capacity 6 x 2,000 ml or 12 x 750 ml blood bag system
- Cooling effectiveness
- Control from – 20 °C to + 40 °C (with model 5005-50 from – 20 °C to + 90 °C).
- Memory 89 programs.
Technology
- Frequency control, No maintenance required
- Electric lock for lid
- The convenient handle closes the lid easily
- Large viewing port on the cover for speed calibration using an optical meter.
Safe
- Stop centrifugation when imbalance
- Get automatic rotor
- The switch locks and protects the programs
- Lock and hold the lid
- Protects against falling cover
- Overheating protection of the motor and centrifugal chamber
- Stainless steel frame
- Surface smooth, easy to clean
Screen
- With S panel to meet the highest standards. Many functions with just a few user taps.
- The display is clearly arranged easy to read with selection buttons and adjustment knobs it brings high user friendliness. The controls and displays of the ROTO SILENTA 630RS are arranged according to ergonomic aspects. During the centrifugation process, the values of all parameters are displayed
Accessory:
Túi máu có thể được đảm bảo trong bộ điều hợp sử dụng HettLiners. Sau khi ly tâm, chúng có thể được loại bỏ bằng vòng gắn trên nó mà không làm xáo trộn phân lớp
Trong trường hợp không có đủ hệ thống túi máu để cân bằng vị trí của rotor, các vị trí trống có thể được cần bằng với bộ trọng lượng cùng với phần chèn có thể được sử dụng
Trong trường hợp không có đủ hệ thống túi máu để cân bằng vị trí của rotor, các vị trí trống có thể được cần bằng với bộ trọng lượng cùng với phần chèn có thể được sử dụng